Hayward Pool Heater Troubleshooting (2024)

When it comes to troubleshooting Hayward pool heater error codes, there's not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. The components of a Hayward pool heater are also similar to gas heaters made by other manufacturers.

Gas fired pool heaters are similar to a home gas-fired furnace, with the main difference being that a pool heater heats water and a home furnace heats air. Big difference, but other than that, they operate pretty much the same!

Troubleshooting Hayward Gas Heater Error Codes

Below is the troubleshooting guide for Hayward pool heater error codes. Error codes show up on the digital screen of the H-Series H150, H200, H250, H300, H350, and H400 gas models.Work through the chart below if your heater displays the following error codes.

CodeDescriptionInformation
bDInternal fault/power-up errorOn initial trial for ignition. Automatic reset is immediate once the gas valve relay check results are acceptable.
bDGas valve sensed as “ON” errorIf valve is open when it should be closed the heater will shut down and go into lockout. Blower will operate until error condition is corrected. Automatic restart 2 minutes after error is corrected.
bDGas valve sensed as “OFF” errorIf valve is closed but flame is sensed the blower will run for 5 seconds, then start a new ignition sequence. If error occurs 10 times during a call for heat the control will go into lockout. Automatic reset is 60 minutes.
bDData retrieval errorIf control input data is corrupts, the heater will shut down and lockout.
HFFlame present with gas valve “OFF” errorIf flame is sensed with the gas valve off the control will go into lockout. The blower will run until error condition is corrected. When corrected, control will run blower for 5 s then automatically restart after 2 minutes.
PFElectrical supply wiring errorThis code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. Reset is immediate after error is corrected.
AOBlower vacuum switch open errorIf the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout. The blower will continue to run. Automatic reset is immediate after the switch closes
AOBlower vacuum switch open when expected closed errorIf the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. If the switch does not close after the blower starts the control will go into lockout with the blower running. Automatic reset is immediate after error is corrected.
AOBlower vacuum switch open during post-purge errorIf the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. The post-purge cycle will be completed once the blower prover switch closes.
ACBlower vacuum switch closed when expected open errorIf the blower prover switch is closed before blower start-up the control will not start the blower. Automatic reset is immediate when the switch opens
IOIgniter open errorIf the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. Automatic restart 2 min after error is corrected.
SFThermistor errorAn excessive temperature difference between the two thermistors (5 °F or more) or an “out of bounds” condition on both sensors (less than 10°F or greater than 180°F) will result in the error code. Automatic restart is 2 minutes after the error is corrected.
HSWater Temperature Sensing Error
SbKeypad button stuck closed errorIf one of the keypad buttons is closed (or pressed) for more than 30 s the error code will be displayed but the control will continue to function. The error code will be cleared when the condition is corrected.
IFIgnition failure errorIf the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. Automatic reset is 60 minutes.
CECommunication errorIf communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. After communication is established, if it is lost for 30 s, the error will be displayed. The error code will be cleared upon a valid data exchange between boards
LOLimit string open errorIf the limit string opens the heater shuts down and goes into lockout. Automatic restart is 2 minutes after the error condition is corrected and the limit string closes. See below for more detail
EEEEPROM ERRORAn error was detected in the ignition control circuit board.

Troubleshooting Hayward Gas Heaters

Below is a list of common issues that can arise with your Hayward pool heater. Unlike the error codes that show up on the digital screen, these problems don't show up as an error notification. Work through the list below if your Hayward pool heater is on the fritz.

ProblemPossible CausePossible Solution
Heater cycles on & off1. Filter or pump baskets are dirty. 2. External bypass is out of adjustment.
3. Internal bypass is broken or stuck.
4. Pressure switch is out of adjustment.
5. Lime scale in the heat exchanger.
1. Clean filter or baskets.
2. Adjust bypass valve
3. Inspect or repair bypass
4. Adjust the pressure switch
5. Clean or replace the heat exchanger.
Sooting of heat exchanger1. High water flow (>125 gpm) into the heater.
2. Internal bypass is broken or stuck.
3. Lack of air combustion
4. Low gas pressure
5. Improper venting
6. Blocked heat exchanger
7. Blocked burners
1. Install an external bypass
2. Inspect or repair the bypass
3. Improve air flow to the heater
4. Check the gas line size
5. Verify the exhaust is correct
6. Clean the heat exchanger
7. Clean debris off the burners
Pilot outages1. Low gas pressure
2. Restricted gas flow
3. Weak thermopile
4. High winds
5. Broken pilot gas tubing
1. Increase pilot gas pressure
2. Clean pilot orifice
3. Replace the thermopile
4. Install a high wind stack
5. Replace the pilot tubing
Heater does not heat pool enough1. Heater is too small
2. Starting temperature is too low
3. Bad wiring or bad connections
4. Water flow is too low
1. Add a solar cover
2. Add a solar cover
3. Check and repair or replace wiring and connections
4. Adjust bypass for more flow
Heater does not fire or light1. Bad gas valve
2. Pressure switch
3. Thermostat
4. High limits
5. On/Off switch
6. Fireman's switch
1. Use jumper wire to jump "TH" terminals
2. Use jumper wire to jump across wires on the pressure switch
3. Jump wires on thermostat
4. Jump wires on high limits
5. Jump wires on on/off switch
6. Jump wires on fireman's switch

Summary

We hope these charts help solve your Hayward pool heater problems. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, you’re sure to find a solution quickly!

Troubleshooting pool heaters is a methodical process, or a process of elimination. First eliminate water flow issues, then gas flow issues, and finally the low voltage electric currents that run between pool heater components. And if you have Hayward heater error codes on display, that makes finding the problem almost easy!

Hayward Pool Heater Troubleshooting (2024)

FAQs

Why is my Hayward pool heater not firing up? ›

If the heater has not been fired in over a week, chances are there is a blockage in the burners or orifices that is preventing the gas from escaping the burner and reaching the spark. Other causes of this problem are: (1) Bad ignitor. (2) Bad gas valve.

How do I reset my pool heater? ›

Reset your pool heater by flipping the breaker switch in the electrical panel to “off” and then “on.” Your breaker may be located in a disconnect box near your pool heater or in the breaker panel in your home.

Why won't my pool heater ignite? ›

Heater pilot won't light? This could be due to low gas pressure, inadequate air supply, or improper venting. Make sure gas is turned on; and for propane, make sure the tank has fuel. Also check for water run-off from roof or sprinklers that may be flooding the heater.

Why is my pool heater running but not heating? ›

If you notice that the water stays cool even with the heater switched on, try checking the filter and the pressure gauge. If the pump runs, but the pressure metre reads zero or any value close to zero, you know there's something wrong. If the filter isn't the cause of the problem, it might be the heater's size.

Why does my Hayward pool heater fire up then shut off? ›

Why does my heater “cycle” on and off? Inadequate water flow caused by a dirty filter or closed valves. External bypass needs adjusting. Reversed water connections.

What causes ignition lockout on pool heater? ›

Filters and strainers that are clogged—temperature monitoring requires unrestricted flow. Setting the pool heater to over 105°F is a simple technique to generate temperature excesses and lockouts. Solar heat gain—when the pool is not in use, cover it to keep the sun's heat from altering the water temperature.

What causes pool heater failure? ›

There could be low gas pressure, poor ventilation, inadequate air supply, or another problem with the gas line. Insufficient gas supply is often to blame.

Does a pool heater only run when the pump is running? ›

This means that they will only operate when your pool pump is turned on and water is flowing through the heat pump. You can therefore control when your heat pump operates simply by using a time clock on your water pump. Some heat pump models also have a timer built into the digital control panel.

Can a pool heater get clogged? ›

Your pool heater contains a filter that prevents contaminants from circulating through the filter and causing a problem. However, if the filter becomes clogged, it can prevent the correct amount of water from passing through. Without sufficient water pressure, your heater won't be able to work.

Why is my pool not heated? ›

Clean out your pool heater's filters and then power it on. Check and replace your pilot tube if your pool heater won't ignite. Check the gas supply valve and reconnect if disconnected if your pool heater does not come on. Check the vents and that the heater is not flooded where there is poor circulation.

Why is my pool heat pump not turning on? ›

Pool heat pump not turning on

If the timer is correct, there could be a connection issue or your circuit breaker may have been activated. Make sure your unit is plugged in and that the circuit breaker is off. If the pump still doesn't turn on, you may have faulty or corroded wires.

What is the if fault on the Hayward heater? ›

There are different models of Hayward units, some use a spark igniter, some use a glow igniter. Most of the time, the IF code means that the igniter has failed, the gas valve has failed, or on units with flame sensing technology, the flame sensor is dirty and needs to be cleaned with sandpaper.

How do you know if your pool heater is bad? ›

If you notice that your pool water is not reaching the desired warmth or if it fluctuates unexpectedly, it's a clear indication that your heater is struggling. Inconsistent heating may be caused by issues with the thermostat, faulty sensors, or other internal components that need professional inspection and repair.

Top Articles
Latest Posts
Article information

Author: Edmund Hettinger DC

Last Updated:

Views: 6275

Rating: 4.8 / 5 (78 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Edmund Hettinger DC

Birthday: 1994-08-17

Address: 2033 Gerhold Pine, Port Jocelyn, VA 12101-5654

Phone: +8524399971620

Job: Central Manufacturing Supervisor

Hobby: Jogging, Metalworking, Tai chi, Shopping, Puzzles, Rock climbing, Crocheting

Introduction: My name is Edmund Hettinger DC, I am a adventurous, colorful, gifted, determined, precious, open, colorful person who loves writing and wants to share my knowledge and understanding with you.